Solas life raft::Buoyant apparatus inspection checklist

Template Information

Uscg life raft inspection handbook

Category: maritime

Template Questions

  • Name of Liferaft's Vessel
  • Number of Persons
  • Type of Liferaft
  • Liferaft Manufacturer
  • Date of Manufacture
  • Serial Number
  • Add media
  • Inspection Type
  • Use of life raft inspection book: This inspector book is intended to be used as a job aid by Coast Gu
  • Annual Inspection
  • Must be conducted in accordance with IMO Resolution A.689(17), paragraph 2/5.1.5
  • Pressurized and checked for damage and leakageMaybe included as the Working pressure leakage test
  • Inflated until firm and let stand for one hourMust still be firm after one hourSeams connecting floor
  • Replace if passed expiration dateRepaired or replaced if damaged and unserviceable
  • Replaced with a fresh battery if passed expiration dateMeasured voltage is less than rated voltage
  • Inspected and tested as prescribed in the servicing manual unless battery is included aboveEach cell
  • Tested and inspected in accordance with the manufacturer's instruction EEPROM must be tested using th
  • Tested for proper operation
  • Damaged faded or incorrect instruction or identification labels on life raft or containers must be re
  • Each life raft examined to ensure that it is properly marked with retro reflective material Arrangeme
  • Each inflation cylinder must be weighedIf weight loss exceeds 5% of the way of the charge, it must be
  • Must renew: The poppet pin, if any Each plastic or elastomeric seal and other parts that deteriorate
  • Tested in marked in accordance with 49 CFR 173.34
  • Lunching load test conducted at every second servicingTest must be conducted in accordance with IMO R
  • At every 5th in your servicing, each life raft must be removed from its container and inflated by its
  • Life Raft (10 year or greater)
  • If a gas inflated test is not conducted, a "Necessary Additional Pressure" (NAP) test must be conduct
  • Plug or otherwise disable pressure-relief valveGradually raise the pressure to the lesser of 2 times
  • Buoyancy tube supported a sufficient distance above the floor of the servicing facility, a person wei
  • Additional Facility Requirements
  • Servicing facility must permanently mark the life raft outside the canopy, or on a servicing record p
  • Inspection sticker to be affixed to the life raft container, Must be of a type that will remain legib
  • Name of the Manufacturer of the life raftYear and month of the expiration dateIdentification of the s
  • Expiration date of the servicing sticker is 12 months after the date of the life raft repacked, excep
  • Facility must remove and destroy markings of CG approval on each condemned life raft
  • The servicing facility must issue a certificate the life raft owner's agent for each life raft it ser
  • The servicing facility must keep a record of each life raft approved by the Coast Guard for at least
  • Servicing facility must provide OCMI annual statistics showing nature and extent of damage and defect